RM新时代app下载-首页

    <menu id="icv9r"></menu>
    <dd id="icv9r"><meter id="icv9r"></meter></dd>
    <tbody id="icv9r"><meter id="icv9r"><var id="icv9r"></var></meter></tbody>
    1. <tbody id="icv9r"><nobr id="icv9r"></nobr></tbody><strong id="icv9r"><delect id="icv9r"><dl id="icv9r"></dl></delect></strong>

      1. 歡迎進(jìn)入濟南濟柴環(huán)能燃氣發(fā)電設備有限公司官網(wǎng)!

        公司新聞

        瓦斯發(fā)電機組節能環(huán)保安全使用要注意

        返回 2022.07.27 來(lái)源:http://m.elmasticar.com 0
        瓦斯發(fā)電機組雖然節能環(huán)保,但是對操作環(huán)境、配套設備要求較高,隱患較大,如果操作不當,容易釀成災禍。要注意什么呢?
        Although the gas generator set is energy-saving and environment-friendly, it has high requirements for the operating environment and supporting equipment, and has great hidden dangers. If it is operated improperly, it is easy to cause disasters. What should we pay attention to?
        機房設置要合理
        The setting of machine room should be reasonable
        1.瓦斯發(fā)電機組機房一般采用敞開(kāi)式或半敞開(kāi)式,地面要平整易清理。
        1. The machine room of gas generator set is generally open or semi open, and the ground should be flat and easy to clean.
        2.封閉式機房,應按防爆要求設計,須是單層建筑,門(mén)窗一律外開(kāi),設置大流量排風(fēng)裝置,預防可瓦斯體積聚等。
        2. The enclosed machine room should be designed according to the explosion-proof requirements. It must be a single-layer building. All doors and windows should be opened outside, and large flow exhaust devices should be set to prevent gas accumulation.
        3.機房與操作間應隔開(kāi),觀(guān)察窗口應用雙層玻璃,且有鋼絲網(wǎng)防護。
        3. The machine room should be separated from the operation room, and the observation window should be double glazed and protected by steel wire mesh.
        4.機房應設有避雷裝置。
        4. The machine room should be equipped with lightning protection devices.
        5.瓦斯發(fā)電機組運行現場(chǎng)不得有明火,須有明顯的“嚴禁煙火”等標志。
        5. There shall be no open fire on the operation site of gas generator set, and there must be obvious signs such as "no fireworks".
        6.配備充足的滅火器材。
        6. Provide sufficient fire-fighting equipment.
        7.發(fā)動(dòng)機排氣系統的廢氣中,混有可瓦斯體,要設計并安裝由發(fā)動(dòng)機引向室外的排氣管系。
        7. The exhaust gas of the engine exhaust system is mixed with gassable bodies, and the exhaust pipe system led outdoors by the engine should be designed and installed.
        發(fā)電機組及配套設備要達標
        The generator set and supporting equipment should meet the standard
        1.瓦斯發(fā)電機組機房?jì)鹊碾姎庠O施應為防爆型,維修時(shí)要切斷電源。
        1. The electrical facilities in the machine room of gas generator set shall be explosion-proof, and the power supply shall be cut off during maintenance.
        瓦斯發(fā)電機組
        2.設置緊急閥門(mén),以備廠(chǎng)房?jì)劝l(fā)生緊急情況時(shí),可迅速切斷氣源,此閥門(mén)應離操作間較近。
        2. Set up an emergency valve to quickly cut off the air supply in case of an emergency in the plant. This valve should be close to the operation room.
        3.瓦斯發(fā)電機房?jì)纫仓猛咚節舛葓缶?,當環(huán)境濃度在爆炸和中毒濃度范圍以?xún)葧r(shí),強制通風(fēng),降低濃度后方可啟動(dòng)機組。
        3. The gas concentration alarm shall be installed in the gas generator room. When the environmental concentration is within the range of explosion and poisoning concentration, the unit can be started after forced ventilation and concentration reduction.
        瓦斯管道要達標并及時(shí)檢修
        The gas pipeline shall meet the standard and be overhauled in time
        1.瓦斯管道應采用管壁較厚的鋼管,接頭處要密封可靠。
        1. The gas pipeline should adopt the steel pipe with thick pipe wall, and the joint should be sealed reliably.
        2.定期檢查閥門(mén),發(fā)現問(wèn)題要及時(shí)維修或更換。
        2. Check the valve regularly and repair or replace it in time if any problem is found.
        3.瓦斯管線(xiàn)上的膠管應定期更換,禁用老化膠管。
        3. The rubber hose on the gas pipeline should be replaced regularly, and aging rubber hose is forbidden.
        4.對瓦斯發(fā)電機組及瓦斯管線(xiàn)進(jìn)行檢修時(shí),切斷瓦斯來(lái)源并將內部瓦斯排凈,未查明事故原因和采取措施前,不得向瓦斯設施恢復送氣。
        4. When overhauling the gas generator set and gas pipeline, cut off the gas source and drain the internal gas. Before identifying the cause of the accident and taking measures, do not restore gas supply to the gas facilities.
        瓦斯發(fā)電機組在使用過(guò)程中需要多加注意,嚴格按照規章制度操作。在選用瓦斯發(fā)電機組的時(shí)候要選用有資質(zhì)的正規廠(chǎng)家,這樣產(chǎn)品質(zhì)量才有保證??申P(guān)注我們網(wǎng)站http://m.elmasticar.com咨詢(xún)了解!
        The gas generator set needs to pay more attention in the use process and operate in strict accordance with the rules and regulations. When selecting gas generator units, qualified and regular manufacturers should be selected, so that the product quality can be guaranteed. Follow our website http://m.elmasticar.com Consult and understand!
        新聞搜索
        濟南濟柴環(huán)能燃氣發(fā)電設備有限公司
        • 服務(wù)熱線(xiàn)

          0531-62325028
          0531-69951266

        瓦斯發(fā)電機組節能環(huán)保安全使用要注意

        瓦斯發(fā)電機組雖然節能環(huán)保,但是對操作環(huán)境、配套設備要求較高,隱患較大,如果操作不當,容易釀成災禍。要注意什么呢?
        Although the gas generator set is energy-saving and environment-friendly, it has high requirements for the operating environment and supporting equipment, and has great hidden dangers. If it is operated improperly, it is easy to cause disasters. What should we pay attention to?
        機房設置要合理
        The setting of machine room should be reasonable
        1.瓦斯發(fā)電機組機房一般采用敞開(kāi)式或半敞開(kāi)式,地面要平整易清理。
        1. The machine room of gas generator set is generally open or semi open, and the ground should be flat and easy to clean.
        2.封閉式機房,應按防爆要求設計,須是單層建筑,門(mén)窗一律外開(kāi),設置大流量排風(fēng)裝置,預防可瓦斯體積聚等。
        2. The enclosed machine room should be designed according to the explosion-proof requirements. It must be a single-layer building. All doors and windows should be opened outside, and large flow exhaust devices should be set to prevent gas accumulation.
        3.機房與操作間應隔開(kāi),觀(guān)察窗口應用雙層玻璃,且有鋼絲網(wǎng)防護。
        3. The machine room should be separated from the operation room, and the observation window should be double glazed and protected by steel wire mesh.
        4.機房應設有避雷裝置。
        4. The machine room should be equipped with lightning protection devices.
        5.瓦斯發(fā)電機組運行現場(chǎng)不得有明火,須有明顯的“嚴禁煙火”等標志。
        5. There shall be no open fire on the operation site of gas generator set, and there must be obvious signs such as "no fireworks".
        6.配備充足的滅火器材。
        6. Provide sufficient fire-fighting equipment.
        7.發(fā)動(dòng)機排氣系統的廢氣中,混有可瓦斯體,要設計并安裝由發(fā)動(dòng)機引向室外的排氣管系。
        7. The exhaust gas of the engine exhaust system is mixed with gassable bodies, and the exhaust pipe system led outdoors by the engine should be designed and installed.
        發(fā)電機組及配套設備要達標
        The generator set and supporting equipment should meet the standard
        1.瓦斯發(fā)電機組機房?jì)鹊碾姎庠O施應為防爆型,維修時(shí)要切斷電源。
        1. The electrical facilities in the machine room of gas generator set shall be explosion-proof, and the power supply shall be cut off during maintenance.
        瓦斯發(fā)電機組
        2.設置緊急閥門(mén),以備廠(chǎng)房?jì)劝l(fā)生緊急情況時(shí),可迅速切斷氣源,此閥門(mén)應離操作間較近。
        2. Set up an emergency valve to quickly cut off the air supply in case of an emergency in the plant. This valve should be close to the operation room.
        3.瓦斯發(fā)電機房?jì)纫仓猛咚節舛葓缶?,當環(huán)境濃度在爆炸和中毒濃度范圍以?xún)葧r(shí),強制通風(fēng),降低濃度后方可啟動(dòng)機組。
        3. The gas concentration alarm shall be installed in the gas generator room. When the environmental concentration is within the range of explosion and poisoning concentration, the unit can be started after forced ventilation and concentration reduction.
        瓦斯管道要達標并及時(shí)檢修
        The gas pipeline shall meet the standard and be overhauled in time
        1.瓦斯管道應采用管壁較厚的鋼管,接頭處要密封可靠。
        1. The gas pipeline should adopt the steel pipe with thick pipe wall, and the joint should be sealed reliably.
        2.定期檢查閥門(mén),發(fā)現問(wèn)題要及時(shí)維修或更換。
        2. Check the valve regularly and repair or replace it in time if any problem is found.
        3.瓦斯管線(xiàn)上的膠管應定期更換,禁用老化膠管。
        3. The rubber hose on the gas pipeline should be replaced regularly, and aging rubber hose is forbidden.
        4.對瓦斯發(fā)電機組及瓦斯管線(xiàn)進(jìn)行檢修時(shí),切斷瓦斯來(lái)源并將內部瓦斯排凈,未查明事故原因和采取措施前,不得向瓦斯設施恢復送氣。
        4. When overhauling the gas generator set and gas pipeline, cut off the gas source and drain the internal gas. Before identifying the cause of the accident and taking measures, do not restore gas supply to the gas facilities.
        瓦斯發(fā)電機組在使用過(guò)程中需要多加注意,嚴格按照規章制度操作。在選用瓦斯發(fā)電機組的時(shí)候要選用有資質(zhì)的正規廠(chǎng)家,這樣產(chǎn)品質(zhì)量才有保證??申P(guān)注我們網(wǎng)站http://m.elmasticar.com咨詢(xún)了解!
        The gas generator set needs to pay more attention in the use process and operate in strict accordance with the rules and regulations. When selecting gas generator units, qualified and regular manufacturers should be selected, so that the product quality can be guaranteed. Follow our website http://m.elmasticar.com Consult and understand!
        RM新时代app下载-首页

          <menu id="icv9r"></menu>
          <dd id="icv9r"><meter id="icv9r"></meter></dd>
          <tbody id="icv9r"><meter id="icv9r"><var id="icv9r"></var></meter></tbody>
          1. <tbody id="icv9r"><nobr id="icv9r"></nobr></tbody><strong id="icv9r"><delect id="icv9r"><dl id="icv9r"></dl></delect></strong>

              1. <menu id="icv9r"></menu>
                <dd id="icv9r"><meter id="icv9r"></meter></dd>
                <tbody id="icv9r"><meter id="icv9r"><var id="icv9r"></var></meter></tbody>
                1. <tbody id="icv9r"><nobr id="icv9r"></nobr></tbody><strong id="icv9r"><delect id="icv9r"><dl id="icv9r"></dl></delect></strong>

                  1. RM新时代平台网址 RM新时代新项目-百度知道 RM新时代官网 RM新时代新项目-百度知道 RM新时代平台网址 rm新时代足球交易平台 新时代官方下载 RM新时代怎么下载 RM新时代网站 RM新时代正规平台入口