發(fā)電機組啟動(dòng)前應該做哪些工作?
1、檢查傳動(dòng)結構的鏈接螺栓,如果沒(méi)有緊固要緊固好。
1. Check the connecting bolts of the transmission structure, and tighten them if they are not tightened.
2、開(kāi)啟打氣泵的排污閥。
2. Open the blowdown valve of the air pump.
3、檢查離合器手柄壓力是不是正常,超速保險裝置有沒(méi)有定位。
3. Check whether the clutch handle pressure is normal and whether the overspeed safety device is positioned.
4、檢查循環(huán)水泵、燃油泵、機油泵有無(wú)異常。
4. Check whether the circulating water pump, fuel pump and oil pump are abnormal.
5、機房操作人員要遵守安全操作,穿工作服、絕緣鞋,人員要分工明確。
5. Machine room operators should abide by safe operation, wear work clothes and insulating shoes, and the division of labor should be clear.
6、把勵磁電阻置于的電阻位置,并將送電開(kāi)關(guān)關(guān)掉。
6. Put the excitation resistance at the maximum resistance position and turn off the power supply switch.
7、查看貯氣瓶壓力有無(wú)異常。
7. Check whether the pressure of the gas cylinder is abnormal.
8、將各系統管路閘門(mén)設置開(kāi)啟位置。
8. Set the opening position of each system pipeline gate.
9、查看飛輪和發(fā)電機部分防欄桿罩有沒(méi)有損壞。
9. Check whether the guardrail cover of flywheel and generator is damaged.
10、檢查變速箱、調速器、離合器、油位、這些緊固件是否完好,油水溫度不得低于25度才可以啟動(dòng)。
10. Check whether the gearbox, governor, clutch, oil level and these fasteners are in good condition, and the oil-water temperature shall not be lower than 25 ℃.
啟動(dòng)和運行操作:
Start up and run operation:
1、對于停機超過(guò)25h的機組,要先打開(kāi)試動(dòng)閥,并啟動(dòng)機油泵,對于停機超過(guò)7天的機組,得先測量勵磁機及操作電路的絕緣電阻。
1. For the unit shut down for more than 25 hours, the test run valve shall be opened and the oil pump shall be started. For the unit shut down for more than 7 days, the insulation resistance of exciter and operating circuit shall be measured first.
2、柴油發(fā)電機組運轉之后,查看機油壓力表的指示值,如果升到規定值以上必須停止機油泵且要關(guān)閉掃氣泵排污閥,穿好前離合器螺釘。
2. After the diesel generator set is running, check the indicated value of the oil pressure gauge. If it rises above the specified value, the oil pump must be stopped, the drain valve of scavenging pump must be closed, and the front clutch screw shall be put on.
3、發(fā)動(dòng)燃油泵放出管路中的空氣,看看電壓有沒(méi)有在規定的值內,正常,才能進(jìn)行正式啟動(dòng)。
3. Start the fuel pump to release the air in the pipeline, and check whether the voltage is within the specified value, and it can be started formally.
4、察看啟動(dòng)電源的電壓有沒(méi)有符合要求,若電壓正常,可以啟動(dòng)按鈕等發(fā)電機組正常運行后松開(kāi)。
4. Check whether the voltage of the starting power supply meets the requirements. If the voltage is normal, the button can be released after the generator set operates normally.
5、發(fā)電機啟動(dòng)后,即發(fā)電機及全部電氣設備都已帶電,不得伸手接觸帶電部位。
5. After the generator is started, i.e. the generator and all electrical equipment have been charged, do not reach out to touch the live parts.
6、調整發(fā)電機組的轉速,在調整時(shí)必須注意觀(guān)察發(fā)電機運轉有無(wú)異常,正常,集電環(huán)及換向器上的電刷,無(wú)跳動(dòng)、無(wú)冒火花等情況且無(wú)異常響聲。
6. When adjusting the speed of generator set, attention must be paid to observe whether the generator operates normally, whether the brush on the collector ring and commutator does not jump, sparkle and abnormal noise.
7、發(fā)電機啟動(dòng)后,應逐漸提高柴油發(fā)電機組的轉速,并進(jìn)行送電前的檢查。
7. After the generator is started, the speed of the diesel generator set shall be gradually increased, and the inspection before power transmission shall be carried out.
今天小編給大家介紹的是 沼氣發(fā)電機組的相關(guān)知識,更多的精彩內容請點(diǎn)擊我們的網(wǎng)站咨詢(xún):http://m.elmasticar.com我們后續會(huì )有更多的知識為您奉上。
Today, I'd like to introduce to you the relevant knowledge of biogas generating set. For more wonderful contents, please click our website for consultation: http://m.elmasticar.com We will have more knowledge for you.